The NZ Metal Roof and Wall Cladding Code of Practice (COP) is published by NZ Metal Roofing Manufacturers Inc. (MRM), to provide:
- acceptable trade practice for fixing metal roofing, metal wall cladding, and accessories,
- prescriptive detailing for designers, and
- sets a benchmark for the standard of detailing and workmanship required over and above that required to comply with the NZBC.
The COP does not describe or dismiss alternative methods, which may need specific acceptance by the Building Consent Authorities.
It is published in accordance with current technology, materials, and building codes. The COP will be periodically updated to reflect changes in legislation and standards or improvements in technology and available materials.
The most current Code of Practice is available on the MRM website, www.metalroofing.org.nz/cop, as Code of Practice Online (MRM COP Version 26.09).
The latest changes to the NZMRM Metal Roof and Wall Cladding Code of Practice were Published on 1 September 2026.
In one of our busiest revisions yet, v26.09 of the Code of Practice features a long list of new and revised detail drawings.
Important Revisions and New Content
8.10 Flashing Expansion and Contraction and recommendations have been extensively revised, and new detail drawings have been added showing ridge and transverse flashing expansion joints.
We have added 8.11.1 Window Flashing Details for vertical and horizontal corrugated wall cladding. These have been tested to comply with E2/VM1.
The spacing and gap requirements for 5.4.2 Gutter Capacity Designto be categorised as drained along the length specified.
We changed the recommended minimum freeboard for 5.5.3 Bifurcated Valleys to 20 mm and added a recommendation for a valley baffle to be fitted to lower valleys.
To aid in placement of first purlins, we added the positions for first purlins on hips to 8.3D Ridge and Head Flashing Cover Table. The revision also included layout edits to the other tables in 8.4 Flashing Cover, with no changes to recommendations.
New drawings were added to 5.3.3 Minimum Freeboard Values to clearly show the freeboard required for different gutter types.
To reduce ambiguity and improve clarity, we made minor changes to illustrations in the 5.4.7 Gutter Capacity Calculator.
9.4.2.7 Over-Flashing More Than 1m Wide, previously called "Cricket over-Flashing More than 1m Wide", now shows two options for large over-flashings.
In line with manufacturers' literature, we amended the CoP recommendation for 7.1.1 Minimum Roof Cladding Pitch to 3° for trapezoidal profiles with a rib height of 30 mm or more.
A new drawing in 8.5.4.1 Apron and Parapet Capping TerminationsTerminations now shows the preferred termination of an Apron Flashing.
A new clause, 5.4.1.1 External Gutter Designs, contains drawings showing the basic shapes of external gutters.
Editing and Rearrangement without changes to recommendations
The clause 10.10.1.4 Vented Soft Edge has been revised to remove ambiguity.
We added a definition to the 2 Glossary for Solid Fixing and revised the definition of Freeboard to improve clarity.
A new link to the to home page of ECIA will aid in finding the best guidance for Maintenance and Washing of roofs.
8.5.3 Parapet Cappings now clearly show packers required to support various parapet cappings and 10.10.2C Ventilation Pathway: Top Plate with Fleece now shows the correct airflow at the top plate for fleece-lined roof cladding.
The rest of the 26.09 revision consisted of minor errata and changes to layout to aid usability, with no changes to recommendations.