Important Revisions

Most of this revision consisted of editing and rearrangement for clarity, consistency, and accuracy.

  • In Gutter Fall, we amended the MRM recommendation of a 1:200 fall for its effect on the aesthetics of the finished gutter. Although a fall of 5mm in 1m may improve self-cleaning and drainage, it may have an undesireable visual outcome.
  • Our recommendations for making provision for expansion in aluminium were updated in both Roof Cladding Expansion Provisions and Recommendations for Fixing Aluminium to be less restrictive.
  • Metal Cladding Testing was revised to improve understanding of testing requirements. These changes only affect how MRM members will publish testing results, not testing procedures.
  • The entire clause Pressed Metal Tiles was revised and edited, with some information being updated.
  • Warm Roofs were similarly revised and edited. Although there were no substantial changes to recommendations, the content was updated to reflect more modern techniques and approaches.
  • The revision of Warm Roofs included updated details for Insulated Panels Barge Flashing.

Other Edits and revisions

The rest of this update is taken up with minor edits and revisions for clarity, grammar, and spelling.

Important Notice:

In a move to help us better understand our audience and make the NZMRM Metal and Wall Roof Cladding Code of Practice even more useful and relevant, we are introducing an industry selector to the existing registration form. If your particular industry is not listed please select one that is closest.

Registration is important so everybody will be informed of important revisions which is done on a quarterly schedule. You will only receive four emails per year regarding our updates.

The data gathered stays anonymous and will never be shared with anyone outside the NZMRM.

Revision Detail v25.09 - 2025 - September

CategoryClause Number (prior to update)Clause (As of current publication)Details
3 - Substantial change to recommendation5.4.2.1Gutter Fall

Revision to clarify the acceptable and recommended amount of gutter fall.

3 - Substantial change to recommendation7.3.2Roof Cladding Expansion Provisions

Revised Favourable Circumstances for Controlling Expansion to show the correct recommendations for aluminium.

3 - Substantial change to recommendation14.19.2Recommendations for Fixing Aluminium

Changed the recommendation for sheet lengths over 10 m to 3 m.

2 - Editing and rearrangement1Introduction

New revision message for v25.09, published on 1 September 2025.

1 - Minor Errata4.6.3Material Selection

Clarification of C4 and C6 fasteners.

1 - Minor Errata4.10.9Gutter Leaf Guard

Grammar and typo fixes.

1 - Minor Errata4.15.1Ground Clearance

Typo fix.

1 - Minor Errata5.4.7Gutter Capacity Calculator

Updated label of "Span length of roof" on Secret Gutter for clarity.  This previously stated "Length of roof", which was ambiguous: calculations are unchanged.

The enforced minimum remains unchanged at 2.2.

2 - Editing and rearrangement5.6.2Sumps

Clarifying edit.

2 - Editing and rearrangement5.7Downpipes

This clause was renamed, and some content was moved to Rainwater Heads, Sumps, and Overflows. Minor edit for clarity: removed the reference to astragalus. No other changes to content or recommendations.

2 - Editing and rearrangement7.4End Laps

Removed historical error regarding the use of rivets.

2 - Editing and rearrangement8.5.2Barge And Verge

Added illustrations showing details for

1 - Minor Errata8.5.4Apron Flashings

Deleted "optional cation" statements.

2 - Editing and rearrangement8.5.4.4Eaves Flashing

Updated and renamed Gutter-Eaves Flashing and introduced option 2.

1 - Minor Errata10.10.1.2Fascia Vents

Typo fix.

1 - Minor Errata10.10.2Battens

Typo fix.

1 - Minor Errata10.11.1Underlay Standards

Aligned some table items.

1 - Minor Errata10.11.6Installing Underlay

Typo Fix.

1 - Minor Errata10.12.4The Mechanics of Condensation

Typo fix.

1 - Minor Errata10.12.7Water Vapour Pressure

Typo fix.

1 - Minor Errata11Natural Light

Typo fix.

1 - Minor Errata11.1.1Compliance

Typo fix.

1 - Minor Errata11.3.1Point Load on Translucent Sheets

Typo fix.

2 - Editing and rearrangement11.4Thermal Resistance

Updated illustration: Double-Skinned Rooflight.

1 - Minor Errata12.1.3Thermal Noise

Grammar fix.

1 - Minor Errata12.2Purlin Creasing

Punctuation fix.

1 - Minor Errata12.3Flashing Buckling

Punctuation fix.

1 - Minor Errata12.4.3Installation

Some grammar fixes.

1 - Minor Errata12.5.1Touch-Up

Grammar fix.

1 - Minor Errata14.1Overhang

Minor layout edit.

1 - Minor Errata14.1Pre-Installation

Typo fix.

1 - Minor Errata14.5Walking On Roofs

Typo fix.

1 - Minor Errata14.9Marking and Cutting

Typo Fix.

 

1 - Minor Errata14.12.1Nails

Punctuation fix.

1 - Minor Errata14.12.2Screws

Punctuation fix and reformatted font in illustrations for consistency.

1 - Minor Errata14.13.2Fastener Placement

Grammar fix.

1 - Minor Errata14.18.1Roof Cladding Damage

Grammar fix.

1 - Minor Errata14.18.3Correctly Installed Gutters

Typo fix.

1 - Minor Errata14.18.4.1Preventing Swarf Damage

Formatting fix.

1 - Minor Errata14.19Fixing Aluminium Sheeting

Punctuation fix. Added clarifying statement for using aluminium screws.

1 - Minor Errata14.19.1Painted Aluminium

Typo fix.

1 - Minor Errata15Other Products

Punctuation fix.

1 - Minor Errata15.1Curved Roofs

Grammar fix.

2 - Editing and rearrangement15.3.1Design

This clause was revised as part of a comprehensive revision of the parent clause, Pressed Metal Tiles.

2 - Editing and rearrangement15.3.1.1Durability

This clause was comprehensively edited during a comprehensive revision of Pressed Metal Tiles.

 

4 - Clause Inserted Structure

A new clause, created as part of a comprehensive revision of Pressed Metal Tiles

2 - Editing and rearrangement15.3.1.2Minimum Pitch

This clause was edited as part of a comprehensive revision of Pressed Metal Tiles.

2 - Editing and rearrangement15.3.1.3Underlay

This clause was edited as part of a comprehensive revision of Pressed Metal Tiles.

2 - Editing and rearrangement15.3.1.4Roof Framing

This clause was edited as part of a comprehensive revision of Pressed Metal Tiles.

2 - Editing and rearrangement15.3.1.5Tiling Battens

This clause was edited during a comprehensive revision of Pressed Metal Tiles. We introduced a table for Batten Installation, replacing the multiple tables in Pullout resistance for different constructions (which was removed).

0 - Clause Removed15.3.1.5Pullout resistance for different constructions

This clause was removed during an overall revision of Pressed Metal Tiles, and replaced with Batten Installation in Tiling Battens.

2 - Editing and rearrangement15.3.2Valleys

This clause was edited as part of a comprehensive revision of Pressed Metal Tiles.

4 - Clause Inserted Installation

A newly created clause as part of a comprehensive revision of Pressed Metal Tiles.

2 - Editing and rearrangement15.3.3Roof Traffic

This clause was edited as part of a comprehensive revision of Pressed Metal Tiles.

2 - Editing and rearrangement15.3.4Valley Installation

This clause was edited as part of a comprehensive revision of Pressed Metal Tiles.

2 - Editing and rearrangement15.3.5Flashings

This clause was edited as part of a comprehensive revision of Pressed Metal Tiles.

2 - Editing and rearrangement15.3.5.1Ridge

This clause was edited as part of a comprehensive revision of Pressed Metal Tiles.

2 - Editing and rearrangement15.3.5.3Gable Ends

This clause was edited as part of a comprehensive revision of Pressed Metal Tiles.

2 - Editing and rearrangement15.3.5.4Flashing Metal Tile to Wall

This clause was edited as part of a comprehensive revision of Pressed Metal Tiles.

2 - Editing and rearrangement15.3.5.5Diverters

This clause was renamed and edited as part of a comprehensive revision of Pressed Metal Tiles.

1 - Minor Errata15.3.5.6Penetrations

Typo fixes.

2 - Editing and rearrangement15.3.6Longrun Tiles

This clause was edited as part of a comprehensive revision of Pressed Metal Tiles.

1 - Minor Errata15.3.7Sitework

Fixed links.

2 - Editing and rearrangement15.3.8Laying Metal Tiles

This clause was edited as part of a comprehensive revision of Pressed Metal Tiles.

2 - Editing and rearrangement15.3.9Workmanship

This clause was edited as part of a comprehensive revision of Pressed Metal Tiles.

1 - Minor Errata15.4.13.4Finishing at Ridges and Eaves of Tray Roofing

Typo fix.

2 - Editing and rearrangement15.5.1.3Insulated Panel Face Profiles

Updated profile illustrations.

1 - Minor Errata15.5.1.6Insulation Panel Insulation Values

Typo and grammar fix.

2 - Editing and rearrangement15.5.1.18Insulated Panel Flashings

Replaced Insulated Panels Barge Flashing detail for accuracy.

2 - Editing and rearrangement15.5.2Composite Systems

Editing for clarity.

2 - Editing and rearrangement15.5.2.2Composite System Installation

Edited for clarity and accuracy.

1 - Minor Errata16.1Maintenance Compliance

Typo fix.

1 - Minor Errata16.6Special Maintenance

Typo fix.

2 - Editing and rearrangement16.8.2Paint Application

Clause renamed for clarity.

2 - Editing and rearrangement17.1.2Test Requirements

Edit for clarification.

2 - Editing and rearrangement17.1.4Test Report

Edit for clarification.

2 - Editing and rearrangement17.1.5.2Interpreting UDL Load Results

Edit for clarification.

1 - Minor Errata17.1.5.3Interpreting Point Load Results

Typo fix.

1 - Minor Errata17.2.3.1Site Testing

Typo fix.

1 - Minor Errata17.2.5Weatherproofing

Typo fix.

1 - Minor Errata17.3.1Soft Edge Product Technical Statement Requirements

Typo fix.

1 - Minor Errata17.4.1Part1: AS/NZS 2728:2013

Typo fix.

1 - Minor Errata17.4.4Appendices of AS/NZS 2728:2013 included as Normative in the MRM Standard

Typo Fix

1 - Minor Errata17.4.5Appendices of AS/NZS 2728:2013 considered Informative in the MRM Standard:

Typo fix.

1 - Minor Errata18Useful Information

Typo fix.

1 - Minor Errata18.1Conversion Factors

Text styling.

1 - Minor Errata18.3Material Density, Melting Point, Expansion And Modulus

Typo fix.

1 - Minor Errata18.4Decadic Number System

Typo fix.

1 - Minor Errata18.8Sheet Metal Work For Roofing Contractors.

Typo fix.

4 - Clause Inserted v25.09 September 2025

Revision details for the update on 1 September 2025.

(optional caption)
Clause: 
019_002_000_000_000_000_000_000_000
Clause Number: 
19.2
/cop/revision-history/v2509-september-2025
Revision Category: 
4 - Clause Inserted
Revision Detail: 

Revision details for the update on 1 September 2025.