Wind ZoneBatten SizeMax SpanSpacingFixing TypeAlt Fixing
Capacity (kN)
Low50x409003701/90x3.15 gun nail0.55
50x5012003501/90x3.15 gun nail0.55
Medium50x409003701/90x3.15 gun nail0.55
50x5012003502/90x3.15 gun nail0.8
High50x409003702/90x3.15 gun nail0.8
50x5012003501/10gx80mm self-drilling screw2.4
Very High50x409003702/90x3.15 gun nail0.8
50x5012003501/10gx80mm self-drilling screw2.4
Extra High50x409003701/10gx80mm self-drilling screw2.4
50x5012003501/10gx80mm self-drilling screw2.4
 
 
Clause Number: 
15.3.2.4A