In one of our busiest revisions yet, v26.09 of the Code of Practice features a long list of new and revised detail drawings. 

Important Revisions and New Content 

  • Flashing Expansion Details and recommendations have been extensively revised, and new detail drawings have been added showing ridge and transverse flashing expansion joints.

  • We have added Window Flashing Details for vertical and horizontal corrugated wall cladding. These have been tested to comply with E2/VM1.

  • The spacing and gap requirements for residential spouting with overflow to be categorised as drained along the length specified.

  • We changed the recommended minimum freeboard for  Bifurcated Valleys to 20 mm and added a recommendation for a valley baffle to be fitted to lower valleys.

  • To aid in placement of first purlins, we added the positions for first purlins on hips to Ridge and Head Flashing Cover Table. The revision also included layout edits to the other tables in Flashing Cover, with no changes to recommendations.

  • New drawings were added to Minimum Freeboard Values to clearly show the freeboard required for different gutter types.

  • To reduce ambiguity and improve clarity, we made minor changes to illustrations in the Gutter Capacity Calculator.

  • Cricket Over-Flashing More Than 1 m Wide, previously called "Cricket over-Flashing More than 1m Wide", now shows two options for large over-flashings.

  • In line with manufacturers' literature, we amended the CoP recommendation for Minimum Roof Cladding Pitch to 3° for trapezoidal profiles with a rib height of 30 mm or more.

  • A new drawing in Parapet And Apron Capping Terminations now shows the preferred termination of an Apron Flashing.

  • A new clause, External Gutter Designs, contains drawings showing the basic shapes of external gutters.

Editing and Rearrangement without changes to recommendations

  • The clause Vented Soft Edge has been revised to remove ambiguity.

  • We added a definition to the Glossary for Solid Fixing and revised the definition of Freeboard to improve clarity.

  • A new link to the to home page of ECIA will aid in finding the best guidance for Maintenance and Washing of roofs.

  • Parapet Cappings now clearly show packers required to support various parapet cappings and Ventilation Pathway: Top Plate with Fleece now shows the correct airflow at the top plate for fleece-lined roof cladding.

The rest of the 26.09 revision consisted of minor errata and changes to layout to aid usability, with no changes to recommendations.


(item needs a title)

CategoryClause Number (prior to update)Clause (As of current publication)Details
3 - Substantial change to recommendation8.10Flashing Expansion and ContractionSubstantial revision with new recommendations and new details for expansion joints in flashings.
3 - Substantial change to recommendation8.10.1Flashing Buckling Due to Timber ShrinkageThis clause was part of a complete revision of Flashing Expansion Details.
4 - Clause Inserted Flashing Buckling Due to Thermal MovementA new clause created during the revision of Flashing Expansion Details.
4 - Clause Inserted Recommended Expansion Joint Spacing for FlashingsNew clause created during the revision of Flashing Expansion Details.
4 - Clause Inserted Expansion Details for FlashingsA new clause for expansion joint details for flashings.
4 - Clause Inserted Window Flashing DetailsA new clause showing window flashing details which were tested to comply with E2/VM. 
3 - Substantial change to recommendation5.4.2Gutter Capacity DesignNow defining the minimum size for residential spouting overflow.  
2 - Editing and rearrangement1, 1IntroductionNew revision message for v26.09, published on 1 September 2026.
2 - Editing and rearrangement2.1, 2.1DefinitionsUpdated definition for Lap Tape.
4 - Clause Inserted External Gutter DesignsNew illustrations showing different external gutter shapes.
1 - Minor Errata5.4.7Gutter Capacity CalculatorChange illustration label from 'Depth' to 'Upstand' for consistency with input box and clarified instructions for calculator use.
2 - Editing and rearrangement5.5.3Bifurcated Valleys 
2 - Editing and rearrangement7.1.1Minimum Roof Cladding PitchChanged the minimum pitch for symmetrical trapezoidal > 30mm to 3° to bring it in line with manufacturers' recommendations.
2 - Editing and rearrangement8.4Flashing CoverLayout changes to the cover tables to improve usability.
2 - Editing and rearrangement8.5.2Barge And VergeAdjusted the layout of drawings into two columns to improve navigation. No changes to recommendations.
2 - Editing and rearrangement8.5.3Parapet CappingsUpdated detail drawings for parapet caps.
2 - Editing and rearrangement8.5.4.1Apron and Parapet Capping TerminationsTitle edit, layout change, and a new drawing showing details for Apron Terminations.
4 - Clause Inserted8.11Wall CladdingNew drawing showing a Proprietary Wall Vent Cover.
1 - Minor Errata9.4.2.6Penetration Flashings on Trapezoidal ProfilesImage resizing.
3 - Substantial change to recommendation9.4.2.7Over-Flashing More Than 1m WideNew drawings showing alternative details.
1 - Minor Errata9.4.3Dormer DetailsReformatting of Gable Dormer Valley: Corrugate. No other edits or changes to recommendations.
2 - Editing and rearrangement10.10.1.4Vented Soft EdgeEditing to remove ambiguity
2 - Editing and rearrangement10.10.2BattensEditing of Ventilation Pathway: Top Plate with Fleece.
2 - Editing and rearrangement14.18.5Colour Matching PaintRevised for clarity.
2 - Editing and rearrangement16Maintenance Added a link the home page of the Exterior Cleaning Industry Association.
2 - Editing and rearrangement16.7WashingAdded link to ECIA homepage.
4 - Clause Inserted v26.09 September 2026Latest revision.