In the March 2026 revision of the Code of Practice the focus was heavily towards clarification with some substantial changes.
Important Revisions
- We thoroughly revised Ventilation Pathways and all its sub-clauses. This revision included updating illustrations of ventilation pathways and revising the recommendations around ventilated battens.
- In another substantial revision we added guidance about Crevice Corrosion/Wet Storage Stain stain caused by incorrectly supported scaffolding.
- We added a new clause discussing Clip Marking on Trough Sections.
- The illustration for Over-flashed Boot with Arrowhead Soaker on Trapezoidal Profile was updated to show the correct details.
Editing and rearrangement
Most editing and rearrangement for this update concentrated on clarifying and removing ambiguities throughout the Code of Practice.
Revision Detail v26.03 - 2026 - March
| Category | Clause Number (prior to update) | Clause (As of current publication) | Details |
|---|---|---|---|
| 2 - Editing and rearrangement | 1 | Introduction | New revision message for v26.03, published on 1 March 2026. |
| 2 - Editing and rearrangement | 2.1 | Definitions | Updated definition for Lap Tape. |
| 3 - Substantial change to recommendation | 4.10.7 | Crevice Corrosion/Wet Storage Stain | Added guidance for scaffolding support on roofing. |
| 2 - Editing and rearrangement | 4.19.1 | Fastener Durability | Edited for clarity. No changes to recommendations. |
| 2 - Editing and rearrangement | 8.6 | Fastening Flashings | Editing for clarity. |
| 2 - Editing and rearrangement | 8.8 | Profile Closures | Editing for grammar and clarity. No changes to recommendations. |
| 1 - Minor Errata | 9.4.1.1 | Overflashed Backflashings | Renamed clause, for linking purposes. |
| 2 - Editing and rearrangement | 9.4.2.6 | Penetration Flashings on Trapezoidal Profiles | Updated the illustration to show the apron of the cricket covering the penetration apron. |
| 1 - Minor Errata | 9.4.3 | Dormer Details | Reformatting of Gable Dormer Valley: Corrugate. No other edits or changes to recommendations. |
| 2 - Editing and rearrangement | 9.5.1 | Boot Flashings to an Over Flashing | Replaced details drawing: Over-flashed Boot with Arrowhead Soaker on Trapezoidal Profile |
| 0 - Clause Removed | 9.5.2 | Other Applications for Boot Flashings | Removed empty clause. |
| 3 - Substantial change to recommendation | 10.1 | Ventilation Pathways | This clause and its sub-clauses have been substantially revised. |
| 1 - Minor Errata | 10.10.1.1 | Soffit Vents | Small layout fix. |
| 2 - Editing and rearrangement | 10.10.1.2 | Fascia Vents | This clause has been revised as part of the larger revision of Ventilation Pathways. |
| 2 - Editing and rearrangement | 10.10.1.3 | Ridge Vents | This clause has been revised as part of the overall revision of Ventilation Pathways. |
| 1 - Minor Errata | 10.10.1.4 | Vented Soft Edge | Spacing fixes. |
| 2 - Editing and rearrangement | 10.10.2 | Battens | This clause has been revised during the overall review of Ventilation Pathways and the drawings have been updated. |
| 4 - Clause Inserted | Clip Marking on Trough Sections | New clause. | |
| 1 - Minor Errata | 15.4.7 | Sarking | Text formatting. |
| 2 - Editing and rearrangement | 15.4.12 | Canning and Purlin Creasing | Revised definition (see Glossary ), and added a specifications for lap tape and HD tape as an alternative backer for tray roofing. |
| 2 - Editing and rearrangement | 17.1.3.2 | Point Load Testing | Removed wrongly placed image. |
| 1 - Minor Errata | 17.1.5.2 | Interpreting UDL Load Results | Typo Fix. |
| 2 - Editing and rearrangement | 18 | Useful Tools | Renamed the clause to Useful Information. |
| 1 - Minor Errata | 18.5 | Geometry And Measurement | Replaced some illustrations with better waulity ones. No changes to recommendations. |
| 1 - Minor Errata | 18.6 | Velocities | Removed superfluous captions. |
| 1 - Minor Errata | 18.7 | Cricket Penetration Patterns | Replaced copied drawings with original illustrations. No changes to recommendations. |
| 1 - Minor Errata | 18.8 | Sheet Metal Work For Roofing Contractors. | Replaced copied drawings with original illustrations. No changes to recommendations. |
| 4 - Clause Inserted | v26.03 March 2026 | Revision detail for the update on 1 March 2026 |