Screw Fasteners

A fastener penetration of three threads through the steel member is sufficient for the fastener to meet its full design capacity.  Pull-out failure of screws must be checked when assessing a profile's load/span capacity.

The pull-out values of screws into light gauge steel battens or purlins varies greatly with thread design, pitch, and drill point shape. When fastening into light gauge steel, the pull-out values of the specified screw must be considered, and the installation must be completed with that type, gauge, and brand of screw. In light gauge steel under 1mm in thickness, it is also important to avoid stripping out the formed screw thread

Clause: 
003_012_001_000_000_000_000_000_000
Clause Number: 
3.12.1
/cop/structure/fastener-performance#screw-fasteners
Revision Category: 
0 - Clause Removed
Revision Detail: 

This clause has been merged with Steel Purlins Thinner Than 1 mm.

Draft Clause: 
003_012_001_000_000_000_000_000_000