Test Requirements
Uniformly distributed Load (UDL)
- Serviceability tests:
- Deflection under load.
- Permanent deformation or cracking around the fastener head, or de-indexing or de-clipping of clip fastened profiles. Serviceability failure of clip-fastened products may occur when a clip disengages from the central rib, but the weathertightness of the lap is not affected, and the roof can continue to resist increased loads.
- Strength tests.
Strength tests are defined as: sheet unable to resist further loads, i.e. pull-off from clips, buckling, tearing or pull-through of fasteners.
Point Load
- Resistance to point load on the pan, or to two ribs of narrow profiles, at the weakest point.
- Residual deflection after imposition of serviceability load and application of strength load
- Resistance to point load on a single rib at the weakest point.
- Residual deflection after imposition of serviceability load and application of strength load
Load is applied in a downward direction through a rubber-faced pad. The weakest point is generally mid-span at the rib/pan adjacent to the underlap.
Clause:
017_001_002_000_000_000_000_000_000
Clause Number:
17.1.2
/cop/testing-and-mrm-standards/metal-cladding-testing#test-requirements
Revision Category:
2 - Editing and rearrangement
- Log in to post comments