Flashing Cover

The weathertightness of a flashing is determined by the flashing cover (C), not the flashing dimension.(D)  Other considerations are catchment area, wind exposure, roof pitch and profile height.

The minimum flashing cover (C) must correlate with the tables below.

There are four categories of exposure or pitch that determine the required flashing cover.

Category A:

  • Low, Medium or High Wind Zones, all pitches
  • Very High and Extra High Wind Zones where the pitch is equal to or greater than 10°.

Category B:

  • Very High where the pitch is less than 10°, and
  • Extra High Wind Zones all pitches. 

Category C:

  • SED Wind Zones up to 60 m/s, all pitches.

Category D:

  • SED up to 68 m/s, all pitches.

NOTE: These tables are relevant to profiles with a rib height of 17 – 34 mm. Longitudinal flashings over profiles with a rib height greater than 34 mm may have one rib overlap. Dimensions provided in these tables are nominal and may vary slightly due to differences in manufacturing processes from different manufacturers.

Ridge and Head Flashing Cover Table

DimensionCategory
 ABCD
C1130200200

200
+ baffle

Ridge TypeStandardWideWideWide
     
First Purlin Position X for Standard Ridge
Pitch10°15°20°25°30°35°45°
Ridges166164162154149143138124
Hips169167164160157153150143
First Purlin Position X for Wide Ridge
Pitch10°15°20°25°30°35°45°
Ridges236234229224219213208194
Hips239237234230227223220213
 

 

 

Barge Flashing Cover — Trapezoidal and Secret Fixed Table

 
 Category
DimensionABCD
C2 upstands1222+
undersoaker
C1(smooth
surface)
50757575
C1 (profiled
surface)
75100125125

 

 

 

Barge Flashing Cover — Corrugate Table


Dimension


A

Category
B


C


D

C2 upstands2232 +
undersoaker
C1 (smooth surface)50757575
C1 (profiled surface)75100125125

 

 

Transverse Apron Flashing Cover Table


Dimension


 A

Category
B


C


D

C1 mm (smooth
surface)
50 +
hem or
75
75 +
hem or
100
100+
hem or
125

100+
hem or
125

C1 mm (profiled
surface)
75 +
hem or
100
100 +
hem or
125
125125
C2130200200
 
200 +
baffle
 

Apron Flashing Cover – Trapezoidal Table


Dimension


A

Category
B


 C


D

C2 upstands12*22 +
undersoaker
C1 mm (smooth
surface)
50 +
hem
or 75
75 +
hem
or 100
100 +
hem or
125

100+
hem or
125

C1 mm (profiled
surface)
75 +
hem or
100
100 +
hem or
125
125125
*Not to exceed 300 mm. Two ribs cover can consist of two machined crests or one machined crest plus an upstand, hand-formed from the adjacent pan.

Apron Flashing Cover – Corrugate Table


Dimension


A

Category
B


C


D

C2 upstands2232 +
undersoaker
 
C1 upstands (smooth
surface)
50+
hem
or 75
75 +
hem
or 100
100 +
hem or
125
100 +
hem or
125 
 
C1 upstands (profiled
surface)
75 +
hem or
100
100 +
hem or
125
125 +
hem
125
 

Parapet Cap Cover Table


Dimension


A

Category
B


C


D

C1 (smooth
surface)
50757575
C1 (profiled
surface)
75100125125
 

Change of Pitch Flashing Cover Table


Dimension


A

Category
B


C


D

C1250250300300
C2150200200200 +
baffle
 

 

Clause: 
008_004_000_000_000_000_000_000_000
Clause Number: 
8.4
/cop/flashings/flashing-cover
Revision Category: 
2 - Editing and rearrangement
Revision Detail: 

Layout changes to the cover tables to improve usability.