Purlin Protection

Because of expansion movement, safety mesh will cause damage to the plastic sheeting at the purlin line, and it should be isolated at the purlin. This protection should be a foam tape or other durable and non-absorbent material and be of sufficient thickness and resilience to avoid damage. It should extend the full width of the purlin flange and should include both purlins where purlins are lapped .

When plastic roof lighting is laid over safety mesh or wire netting, protection must be placed over the mesh or netting to avoid damage to the underside of the plastic roof lighting.

 

Clause: 
014_008_006_000_000_000_000_000_000
Clause Number: 
14.8.6
/cop/installation/translucent-sheeting#purlin-protection
Revision Category: 
0 - Clause Removed
Revision Detail: 

clause removed

Draft Clause: 
013_008_006_000_000_000_000_000_000