Menu

Modes Of Fastener Failure

On most pierce fixed roofs, mode of failure is likely to be pull-over. Where profiled load spreading washers are required to eliminate this, it is important that the specified washer is used. When fastening to light gauge steel purlins, thread strip out may be the lower failure point. The pull-out failure point is very dependent on drill point, thread shape, and pitch; it is essential in such cases to use a correctly specified fastener.

Pull-Over

(optional caption)

Pull Out

(optional caption)

Thread Strip Out

(optional caption)

Back Out

(optional caption)
Clause: 
014_015_000_000_000_000_000_000_000
Clause Number: 
14.15
/cop/installation/modes-fastener-failure
Revision Category: 
4 - Clause Inserted
Revision Detail: 

Clause revised for clarity

Draft Clause: 
013_006_003_000_000_000_000_000_000