Menu

Ridge And Hip

The method that is used to finish the ridge and a double standing seam depends on whether the type of ridge detail is vented, has a separate ridging, is welted, and whether it is a standing seam or a roll.

Where the panel passes over the ridge or hip of a roof, a roll not less than 38 mm higher than the intersecting rolls or standing seams should be provided. The ridge roll should be undercut to accommodate thermal movement of the panels.

An alternative edge finish is to flatten the seam similar to that shown in Standing Seam Edges.

 

Welted Ridge

(optional caption)

 

 

 

 

Separate Ridge

(optional caption)

 

 

 

 

 

Clause: 
015_004_009_001_000_000_000_000_000
Clause Number: 
15.4.9.1
/cop/other-products/standing-seam-cladding#ridge-and-hip
Revision Category: 
0 - Clause Removed
Revision Detail: 

Clause removed during a comprehensive revision of Standing Seam Cladding.

Draft Clause: 